- Configure subinterfaces & pppoe configs
- Track PPPoE details on Linux wireshark for each PPPoE account
- Find PPPoE server AC names with Wireshark:
pppoe -I enp9s0.X -d
- There's
nw_rt_ssr8010_02_35mndrs-DH80017699
& nw_rt_ssr8010_01_35mndrs-DH80017668
- 02/10/2021: As of now, there's only one Access Concentrator called "Huawei"
nw_rt_ssr8010_02_35mndrs-DH80017699
always gets picked automatically.
- On this server, some accounts are assigned public IPs, some aren't.
- Different gateway IPs are advertised on these two PPPoE servers for Superonline accounts.
- ALL OF THE Superonline accounts WORK if we connect to the second PPPoE server.
- Second server,
nw_rt_ssr8010_01_35mndrs-DH80017668
, always assigns local IP addresses to apply NAT.
- Website censorship and bandwidth limit work normally on the second server.
Multiple PPPoE connection under the same account using the same PPPoE server
Superonline
- 02/10/2021: As of now, there's only one Access Concentrator called "Huawei".
Terminates the PPPoE connection with "Access number is exceed" message
- Terminates the PPPoE connection
Extranet
- Terminates the PPPoE connection
Vodafone
- Gives local IP without internet access
- Two hosts with local IPs can reach other with 6 Mbps upload speed limit.
D-Smart